The effect of solar chimney layout on ventilation rate in buildings

Asadi, Somayeh, et al. "The effect of solar chimney layout on ventilation rate in buildings." Energy and Buildings 123 (2016): 71-78.
DOI: 10.1016/j.enbuild.2016.04.047

BibTeX RIS

Summary

EnergyPlus simulations of a solar chimney attached to a seven-storey office building in Isfahan compare chimney positions on the south, south-west and south-east sides, and also a central placement against one on the south facade, with wall and glazing materials varied as well. The south-east position ventilates best, since it receives the most radiation and has two absorbing walls. Each chimney supplied enough airflow for the spaces connected to it.

Description written by Solar Tower. The original abstract is available from the publisher via the link below.