Fei F. Cao; Liang Zhao; Huashan Li; Liejin Guo · 10.1016/j.applthermaleng.2012.06.038 https://doi.org/10.1016/j.applthermaleng.2012.06.038 · 2012 · Numerical / CFD · Solar chimney power plant
Applied Thermal Engineering
Numerical / CFD
Solar chimney power plant
2012
Applied Thermal Engineering
journal
main
no
2012-06-28 12:00:00 00003450
performance analysis of conventional and sloped solar chimney power plants in china
2012
Applied Thermal Engineering
Fei F. Cao; Liang Zhao; Huashan Li; Liejin Guo
10.1016/j.applthermaleng.2012.06.038
Summary
A heat transfer model compares a conventional solar chimney power plant with sloped designs whose collectors are tilted at 30° and 60°, across several latitudes in China. Steeper collectors perform better in winter but worse in summer, with about 60° optimal for Lanzhou; sloped plants suit the high-latitude northwest, while conventional plants combined with agriculture suit eastern and southeastern China.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source