Hussain Hamoud Al-Kayiem; K. Yin Yin; Chin Yee Sing · 10.2495/ht120061 https://doi.org/10.2495/ht120061 · 2012 · Hybrid system · Numerical / CFD
WIT transactions on engineering sciences
Hybrid system
Numerical / CFD
2012
WIT transactions on engineering sciences
conference
yes
2012-06-27 12:00:00 00003451
numerical simulation of solar chimney integrated with exhaust of thermal power plant
2012
WIT transactions on engineering sciences
Hussain Hamoud Al-Kayiem; K. Yin Yin; Chin Yee Sing
10.2495/ht120061
Summary
A 2-D CFD model in FLUENT simulates an inclined solar chimney that also recovers waste heat from power-plant flue gases, and is checked against a lab-scale experiment. Hotter flue gas strongly improves performance, by about 75% over the tested temperature rise. Collection efficiency rises with absorber length up to a point and then falls, with about 2.5 m found suitable.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source
PDF (open access)