Xiu-Hong Ren; Lei Wang; Run-Zhe Liu; Lin Wang; Fu-Yun Zhao · 10.1016/j.renene.2020.08.128 https://doi.org/10.1016/j.renene.2020.08.128
Renewable Energy
Building ventilation
Numerical / CFD
2020
Renewable Energy
no
2020-08-29 12:00:00 00002661
thermal stack airflows inside the solar chimney with discrete heat sources: reversal flow regime defined by chimney inclination and thermal rayleigh number
2020
Renewable Energy
Xiu-Hong Ren; Lei Wang; Run-Zhe Liu; Lin Wang; Fu-Yun Zhao
10.1016/j.renene.2020.08.128
Summary
Numerical simulations backed by theoretical analysis examine buoyancy-driven airflow and heat transfer in inclined solar chimneys across Rayleigh numbers and tilt angles of 30–90°. Backflow appears near the glazing above a critical Rayleigh number that falls as the tilt angle grows, and it cuts ventilation. Placing discrete heat sources on the glazing wall stops the reversal and improves airflow.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source