Ramin Mehdipour; Ehsan Mohammadi; Amir Mohammad Babaie Parsa; Hassan Nahalekah · 10.1007/s00231-020-02926-6 https://doi.org/10.1007/s00231-020-02926-6
Heat and Mass Transfer
Experimental
Solar chimney power plant
2020
Heat and Mass Transfer
no
2020-09-18 12:00:00 00002654
thermal and exergy assessment of solar chimney performance in various energy absorptions; using indoor experimental setup
2020
Heat and Mass Transfer
Ramin Mehdipour; Ehsan Mohammadi; Amir Mohammad Babaie Parsa; Hassan Nahalekah
10.1007/s00231-020-02926-6
Summary
Indoor laboratory solar chimney power plant model, with floor heaters standing in for sunlight and an adjustable canopy, used to compare divergent, convergent and collector-less collectors through exergy, Nusselt and Rayleigh analysis. The divergent shape captures the most energy: raising its inlet height increases exergy by up to about 70%, and its average Nusselt number is several times that of the other two shapes.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source