Summary
Estimates the basic dimensions of a 10 MW solar chimney power plant from a model of its airflow and heat exchange, and builds cost models for the main components, the whole plant and generated electricity. Comparing alternative geometries yields an economical layout, identifies what drives collector, chimney and overall costs, and proposes ways to cut them.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.