Theodor W. von Backström; Anthony J. Gannon · 10.1016/j.solener.2003.08.009 https://doi.org/10.1016/j.solener.2003.08.009
Solar Energy
Solar chimney turbine characteristics Theodor W. von Backstrom; Anthony J. Gannon Derives analytical expressions linking the efficiency of a solar chimney power plant's axial turbine to its flow and load coefficients, degree of reaction, and blade-row and diffuser losses, giving optimal designs for a required power or a limited size. Tests on a 720 mm model turbine support the model, and a large plant could reach about 90% peak efficiency, though not at every operating point.
Experimental
Solar chimney power plant
2003
Solar Energy
no
2003-09-16 12:00:00 00004076
solar chimney turbine characteristics
2003
Solar Energy
Theodor W. von Backström; Anthony J. Gannon
10.1016/j.solener.2003.08.009
Summary
Derives analytical expressions linking the efficiency of a solar chimney power plant's axial turbine to its flow and load coefficients, degree of reaction, and blade-row and diffuser losses, giving optimal designs for a required power or a limited size. Tests on a 720 mm model turbine support the model, and a large plant could reach about 90% peak efficiency, though not at every operating point.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.