L. Madan Ananda Kumar; V. Sivaramakrishnan; M. Premalatha; Manojkumar Vivekanandan; Kishore Ramakrishnan · 2016 · Building ventilation · Experimental · Numerical / CFD
Building ventilation
Experimental
Numerical / CFD
2016
no
2016-03-01 12:00:00 00003155
interpretation on result of directions of suction opening on solar chimney coherent with building
2016
L. Madan Ananda Kumar; V. Sivaramakrishnan; M. Premalatha; Manojkumar Vivekanandan; Kishore Ramakrishnan
Summary
A solar chimney attached to a single-storey building in Tiruchirappalli, India, was built and tested with air inlets placed on different sides, alone or in pairs, alongside a CFD model. Ventilation rates varied with inlet position, and a chimney inclined at 50° with a left-side inlet gave the highest airflow; simulations agreed well with measurements.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source