Cristiana Brasil Maia; J.O. Castro Silva; Luben Cabezas‐Gómez; S.M. Hanriot; André Guimarães Ferreira · 10.1016/j.rser.2013.06.020 https://doi.org/10.1016/j.rser.2013.06.020
Renewable and Sustainable Energy Reviews
Energy and exergy analysis of the airflow inside a solar chimney Cristiana Brasil Maia; J.O. Castro Silva; Luben Cabezas‐Gomez; S.M. Hanriot; Andre Guimaraes Ferreira Data recorded on a prototype solar chimney feed a thermodynamic assessment of its internal air stream, applying both energy conservation and second-law reasoning to estimate heat and available-work losses to the environment, plus the resulting second-law efficiency. Of two reference-environment choices compared, adopting the minimum ambient value gave smaller losses and better efficiency than using the time-varying ambient reading.
Experimental
Solar chimney power plant
2013
Renewable and Sustainable Energy Reviews
no
2013-07-31 12:00:00 00003371
energy and exergy analysis of the airflow inside a solar chimney
2013
Renewable and Sustainable Energy Reviews
Cristiana Brasil Maia; J.O. Castro Silva; Luben Cabezas‐Gómez; S.M. Hanriot; André Guimarães Ferreira
10.1016/j.rser.2013.06.020
Summary
Data recorded on a prototype solar chimney feed a thermodynamic assessment of its internal air stream, applying both energy conservation and second-law reasoning to estimate heat and available-work losses to the environment, plus the resulting second-law efficiency. Of two reference-environment choices compared, adopting the minimum ambient value gave smaller losses and better efficiency than using the time-varying ambient reading.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source