Xinping Zhou; Jiakuan Yang; Bo Xiao; Guoxiang Hou; Xing Fang · 10.1016/j.applthermaleng.2008.02.014 https://doi.org/10.1016/j.applthermaleng.2008.02.014 · 2008 · Numerical / CFD · Solar chimney power plant
Applied Thermal Engineering
Numerical / CFD
Solar chimney power plant
2008
Applied Thermal Engineering
journal
main
no
2008-02-21 12:00:00 00003948
analysis of chimney height for solar chimney power plant
2008
Applied Thermal Engineering
Xinping Zhou; Jiakuan Yang; Bo Xiao; Guoxiang Hou; Xing Fang
10.1016/j.applthermaleng.2008.02.014
Summary
A theoretical model, checked against measurements from the Manzanares prototype, is used to find both the tallest chimney that still avoids negative buoyancy and the height giving peak power. Under a standard atmospheric lapse rate, power peaks at about 102 kW for a 615 m chimney, below the maximum height. Both heights grow with larger collectors, and the maximum height rises with lapse rate.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source