← Back to publications

A theoretical and numerical analysis of solar chimney in multi-storey atrium building

Shi, Long, et al. "A theoretical and numerical analysis of solar chimney in multi-storey atrium building." Sustainable Energy Technologies and Assessments 65 (2024): 103797.
DOI: 10.1016/j.seta.2024.103797

BibTeX RIS

Summary

Theoretical and CFD analysis of solar chimneys serving multi-storey atrium buildings with several air inlets. A suitably designed chimney meets the WHO target of 6 air changes per hour even at 200 W/m² of sunlight, with airflow rising as a power function of cavity gap, cavity height, radiation and window width. An experimentally validated model predicts the ventilation rate.

Description written by Solar Tower. The original abstract is available from the publisher via the link below.

Open source