← Back to publications

A simplified analytical approach for evaluation of the optimal ratio of pressure drop across the turbine in solar chimney power plants

Nižetić, Sandro, and Branko Klarin. "A simplified analytical approach for evaluation of the optimal ratio of pressure drop across the turbine in solar chimney power plants." Applied Energy 87.2 (2009): 587-591.
DOI: 10.1016/j.apenergy.2009.05.019

BibTeX RIS

Summary

Proposes a simplified analytical method for estimating what fraction of the total chimney pressure drop should be taken by the turbine in a solar chimney power plant, since this fraction determines power output. The resulting optimal values, mostly between 0.8 and 0.9, agree with earlier work, which makes the method suitable for quick preliminary assessments of plant potential.

Description written by Solar Tower. The original abstract is available from the publisher via the link below.

Open source