Haoyu Wang; Chengwang Lei · 10.1016/j.buildenv.2019.106616 https://doi.org/10.1016/j.buildenv.2019.106616 · 2019 · Building ventilation · Numerical / CFD
Building and Environment
Building ventilation
Numerical / CFD
2019
Building and Environment
journal
main
no
2019-12-28 12:00:00 00002759
a numerical investigation of combined solar chimney and water wall for building ventilation and thermal comfort
2019
Building and Environment
Haoyu Wang; Chengwang Lei
10.1016/j.buildenv.2019.106616
Summary
Using CFD, the authors model a building that pairs a solar chimney with a water-filled wall, varying the glazing, the cavity depth and the volume of water. The arrangement keeps air moving through the day and night at roughly 4 room air changes hourly, and enlarging the cavity to 0.2 m boosts flow by about 14%, while going wider adds little.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source