← Back to publications

Ventilation performance of solar chimney in a test house: Field measurement and validation of plume model

He, Guoqing, et al. "Ventilation performance of solar chimney in a test house: Field measurement and validation of plume model." Building and Environment 193 (2021): 107648.
DOI: 10.1016/j.buildenv.2021.107648

BibTeX RIS

Summary

Field measurements on a solar chimney fitted to the south-east wall of a test house in Hangzhou showed it gave average air change rates of roughly 2–5 per hour around the clock. Solar radiation and the room-to-outdoor temperature difference drove the airflow, the size of the room inlet limited it, and the plume model matched the measured data reasonably well.

Description written by Solar Tower. The original abstract is available from the publisher via the link below.

Open source