Sudaporn Chungloo; Bundit Limmeechokchai · 10.1016/j.renene.2008.05.026 https://doi.org/10.1016/j.renene.2008.05.026 · 2008 · Building ventilation · Experimental · Numerical / CFD
Renewable Energy
Building ventilation
Experimental
Numerical / CFD
2008
Renewable Energy
journal
main
no
2008-07-03 12:00:00 00003939
utilization of cool ceiling with roof solar chimney in thailand: the experimental and numerical analysis
2008
Renewable Energy
Sudaporn Chungloo; Bundit Limmeechokchai
10.1016/j.renene.2008.05.026
Summary
A Thai test building with a solar chimney on its south-facing roof and a chilled metal ceiling on the opposite slope was monitored and modelled with two-dimensional CFD. Pairing the two passive elements gave about twice the average cooling capacity of the chimney alone; in simulations, a colder north ceiling boosted ventilation flow by 12% and lowered air temperature near the room top by up to 0.7 °C.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source