Summary
Simulations based on the Spanish prototype examine how the design of an unpowered wind pressure wheel mounted on a wind-supercharged solar chimney's outlet affects suction and output. Blade angle, airfoil shape and spiral blades were varied; a spiral blade with 72° helicity performed best, adding roughly 15 kW of shaft power through stronger negative pressure at the chimney exit.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.