P.J. Cottam; Philippe Duffour; P. Lindstrand; Paul Fromme · 10.1016/j.enconman.2019.04.074 https://doi.org/10.1016/j.enconman.2019.04.074 · 2019 · Numerical / CFD · Solar chimney power plant
Energy Conversion and Management
Numerical / CFD
Solar chimney power plant
2019
Energy Conversion and Management
journal
main
yes
2019-05-01 12:00:00 00002816
solar chimney power plants – dimension matching for optimum performance
2019
Energy Conversion and Management
P.J. Cottam; Philippe Duffour; P. Lindstrand; Paul Fromme
10.1016/j.enconman.2019.04.074
Summary
A detailed thermodynamic model is used to explore how collector radius and chimney height and radius affect the power output and cost-effectiveness of solar chimney power plants. Component sizes must be matched, chimneys up to about 200 m in radius are needed for outputs near 900 MW, and a simple cost model favours several smaller plants over a single very large one.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source
PDF (open access)