Suhendri; Mochamad Donny Koerniawan; Rea Risky Alprianti · 10.1063/1.5046628 https://doi.org/10.1063/1.5046628 · 2018 · Building ventilation · Numerical / CFD
AIP conference proceedings
Building ventilation
Numerical / CFD
2018
AIP conference proceedings
conference
no
2018-01-01 12:00:00 00002957
solar chimney as a natural ventilation strategy for elementary school in urban area
2018
AIP conference proceedings
Suhendri; Mochamad Donny Koerniawan; Rea Risky Alprianti
10.1063/1.5046628
Summary
CFD simulations compare an urban elementary school building in hot, humid Indonesia with and without a solar chimney to test buoyancy-driven ventilation where wind is weak. The chimney raises mean indoor air speed, but at 1 m and 1.5 m, the heights where seated and standing children breathe, air moves more slowly than in the chimney-free case, since faster flow occurs higher up.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.