Summary
Two-dimensional ANSYS simulations, checked against experimental data, examine how tower height, diameter and shape, and collector diameter, height and slope affect a solar chimney power plant. Tower height and diameter have the strongest influence on output power, a diverging tower works best, and a wider collector raises output, with the best results at a 3.5 m tower and a 4 m collector.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.