← Back to publications

Numerical performance modelling of solar chimney power plants: Influence of chimney height for a pilot plant in Manzanares, Spain

Cüce, Erdem, et al. "Numerical performance modelling of solar chimney power plants: Influence of chimney height for a pilot plant in Manzanares, Spain." Sustainable Energy Technologies and Assessments 39 (2020): 100704.
DOI: 10.1016/j.seta.2020.100704

BibTeX RIS

Summary

A three-dimensional axisymmetric CFD model of the Manzanares pilot solar chimney, checked against on-site measurements and using solar ray tracing with a non-grey radiation model, is used to compare five chimney heights. Taller chimneys raise airflow exponentially and power output roughly linearly while reducing collector heating; a 500 m chimney would give about 134 kW at 0.67% overall efficiency.

Description written by Solar Tower. The original abstract is available from the publisher via the link below.

Open source