Abdallah Bouabidi; Haythem Nasraoui; Ahmed Ayadi; Zied Driss; Mohamed Salah Abid · 10.1615/heattransres.2018024769 https://doi.org/10.1615/heattransres.2018024769
Heat Transfer Research
Experimental
Numerical / CFD
Solar chimney power plant
2018
Heat Transfer Research
no
2018-12-13 12:00:00 00002861
numerical and experimental study of the solar chimney with divergent collector
2018
Heat Transfer Research
Abdallah Bouabidi; Haythem Nasraoui; Ahmed Ayadi; Zied Driss; Mohamed Salah Abid
10.1615/heattransres.2018024769
Summary
Solar chimney power plants whose collector widens toward its outlet are compared with a standard design, testing three degrees of divergence through ANSYS Fluent simulations and measurements on a purpose-built test rig. Collector slope changes the airflow and velocity, and with them the static pressure at the chimney entrance and overall performance; simulated and measured results agree closely.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source