Juvy A. Balbarona
Philippine Engineering Journal
Numerical Analysis of a Solar Chimney Juvy A. Balbarona Two-dimensional CFD simulations of a vertical solar chimney examine how the width of the air gap affects induced airflow under solar irradiance of 200–400 W/m2. An RNG k-epsilon model, checked against experimental measurements, gives about 5.4 air changes per hour for a small container house when the gap is 0.4 m at the highest irradiance.
Building ventilation
Numerical / CFD
2015
Philippine Engineering Journal
no
2015-01-01 12:00:00 00003274
numerical analysis of a solar chimney
2015
Philippine Engineering Journal
Juvy A. Balbarona
Summary
Two-dimensional CFD simulations of a vertical solar chimney examine how the width of the air gap affects induced airflow under solar irradiance of 200–400 W/m². An RNG k-epsilon model, checked against experimental measurements, gives about 5.4 air changes per hour for a small container house when the gap is 0.4 m at the highest irradiance.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source