Dipak Kumar Mandal; Nirmalendu Biswas; Nirmal Kumar Manna; Ali Cemal Beni̇m · 10.1016/j.asej.2023.102390 https://doi.org/10.1016/j.asej.2023.102390
Ain Shams Engineering Journal
Impact of chimney divergence and sloped absorber on energy efficacy of a solar chimney power plant (SCPP) Dipak Kumar Mandal; Nirmalendu Biswas; Nirmal Kumar Manna; Ali Cemal Benim A numerical study is carried out meticulously to scrutinize the impact of different shapes of chimneys like circular (outer dia, dc), convergent (outer dia, 0.5dc), divergent (outer dia, 1.5dc), sudden contraction (outer dia, 0.5dc), and sudden expansion (outer dia, 1.5dc) on the performance of an SCPP. Furthermore, the parametric impact with different chimney divergence angles (CDA,
), and ground absorber slope angle (GSA,
) on the SCPP performance is also scrutinized. Optimum divergence angle (
) enhances the power generation up to ∼ 47% (76 kW) with a horizontal ground absorber surface. An increase or decrease in CDA lessens the power generation. With a sloped ground absorber angle
, the gain in power generation is 60% (82 kW). The study of combination of ground sloped absorber (
) and divergent chimney (
) shows enhancement of the power generation upto 80% (92 kW) more than the classical Manzaranes plant.
Numerical / CFD
Solar chimney power plant
2023
Ain Shams Engineering Journal
no
2023-07-27 12:00:00 00001726
impact of chimney divergence and sloped absorber on energy efficacy of a solar chimney power plant (scpp)
2023
Ain Shams Engineering Journal
Dipak Kumar Mandal; Nirmalendu Biswas; Nirmal Kumar Manna; Ali Cemal Beni̇m
10.1016/j.asej.2023.102390
Abstract
A numerical study is carried out meticulously to scrutinize the impact of different shapes of chimneys like circular (outer dia, dc), convergent (outer dia, 0.5dc), divergent (outer dia, 1.5dc), sudden contraction (outer dia, 0.5dc), and sudden expansion (outer dia, 1.5dc) on the performance of an SCPP. Furthermore, the parametric impact with different chimney divergence angles (CDA,
), and ground absorber slope angle (GSA,
) on the SCPP performance is also scrutinized. Optimum divergence angle (
) enhances the power generation up to ∼ 47% (76 kW) with a horizontal ground absorber surface. An increase or decrease in CDA lessens the power generation. With a sloped ground absorber angle
, the gain in power generation is 60% (82 kW). The study of combination of ground sloped absorber (
) and divergent chimney (
) shows enhancement of the power generation upto 80% (92 kW) more than the classical Manzaranes plant.
Abstract by the authors, reproduced under the CC BY 4.0 licence. Original publication via the link below.