Summary
A numerical model, checked against experiments, is used to assess how seven design and operating parameters affect space heating from a solar chimney with integrated phase change material. Latent heat, heat flux, insulation conductivity, absorber absorptivity, glazing transmissivity and inlet air temperature strongly influence melting and solidification times; higher latent heat roughly doubles melting time, while absorber conductivity matters little.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.