Eya Missaoui; Sami Missaoui; Ahmed Ayadi; Haythem Nasraoui; Zied Driss · 10.1108/wje-09-2025-0653 https://doi.org/10.1108/wje-09-2025-0653
World Journal of Engineering
Experimental
Solar chimney power plant
Thermal storage / PCM
2025
World Journal of Engineering
no
2025-12-19 12:00:00 00001963
experimental study of the effects of the geometrical configurations on the performance of a small prototype solar chimney power plant with sensible heat storage
2025
World Journal of Engineering
Eya Missaoui; Sami Missaoui; Ahmed Ayadi; Haythem Nasraoui; Zied Driss
10.1108/wje-09-2025-0653
Summary
Tests on a small laboratory solar chimney power plant with a water-based heat store examine how water depth in the tank and the spacing between absorber and collector cover affect temperatures and airflow. A water depth of about 6 cm gave the warmest chimney air, whereas widening the collector gap cooled the whole system by weakening natural convection and raising heat losses.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source