Sajad Golzardi; Ramin Mehdipour; Zahra Baniamerian; Ali Ghaffari · 10.2139/ssrn.7412584 https://doi.org/10.2139/ssrn.7412584
SSRN Electronic Journal
Experimental
Solar chimney power plant
2026
SSRN Electronic Journal
no
2026-01-01 12:00:00 00001957
experimental parametric investigation of a unidirectional solar collector for improving thermal performance of solar chimney power plants
2026
SSRN Electronic Journal
Sajad Golzardi; Ramin Mehdipour; Zahra Baniamerian; Ali Ghaffari
10.2139/ssrn.7412584
Summary
Using a reduced-scale laboratory model run indoors, the authors vary tower height, entrance gap, roof slope and heater output on a square collector shaped to push air one way. Performance hinges on managing secondary currents: a lower entrance adds about 6.5% to the energy delivered to the airflow, and a steeper roof adds up to roughly 7%.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source