Laboratory rigs and a validated three-dimensional model with ray tracing and radiation are used to examine a solar chimney for air cleaning whose collector carries photovoltaic panels. Covering about half the collector roof with PV cuts airflow by only 14%. In a Manzanares-sized system, running suction fans on the PV electricity raises total airflow to roughly 2.2–2.4 times that of a PV-free design.