Hussain Hamoud Al-Kayiem; K.V. Sreejaya; Ogboo Chikere Aja · 10.1016/j.enbuild.2017.10.063 https://doi.org/10.1016/j.enbuild.2017.10.063 · 2017 · Building ventilation · Experimental · Numerical / CFD
Energy and Buildings
Building ventilation
Experimental
Numerical / CFD
2017
Energy and Buildings
journal
main
no
2017-11-02 12:00:00 00002999
experimental and numerical analysis of the influence of inlet configuration on the performance of a roof top solar chimney
2017
Energy and Buildings
Hussain Hamoud Al-Kayiem; K.V. Sreejaya; Ogboo Chikere Aja
10.1016/j.enbuild.2017.10.063
Summary
Experiments and 2-D ANSYS FLUENT simulations compare four inlet shapes for the collector of a rooftop solar chimney built over a room model. A vertical inlet gave the highest chimney airflow and velocity, while a horizontal one cut collector performance by about 84%, since most incoming air enters from above the inlet. The authors suggest the canopy area of solar chimney power plants could be reduced.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source