Mehran Rabani; Vali Kalantar; Mehrdad Rabani; Ramin Rabani · 10.18280/ijdne.150311 https://doi.org/10.18280/ijdne.150311
International Journal of Design & Nature and Ecodynamics
Building ventilation
Experimental
2020
International Journal of Design & Nature and Ecodynamics
yes
2020-06-23 12:00:00 00002681
cooling performance of a new designed trombe wall integrated with solar chimney, water spraying system, and rectangular thermal fin arrays: an experimental approach
2020
International Journal of Design & Nature and Ecodynamics
Mehran Rabani; Vali Kalantar; Mehrdad Rabani; Ramin Rabani
10.18280/ijdne.150311
Summary
Experimental tests in a hot, dry climate (Yazd, Iran) of a passive cooling setup in which a Trombe wall is combined with a solar chimney, water spraying and rectangular fin arrays. Spraying water lowered room temperature by as much as 10 °C, while adding fins raised cooling efficiency by up to 6%. Copper fins performed better than aluminium or brass ones.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source
PDF (open access)