Sandeep Kumar Singh Patel; Deepak Divashkar Prasad; Mohammed Rafiuddin Ahmed · 10.1016/j.enconman.2013.09.056 https://doi.org/10.1016/j.enconman.2013.09.056
Energy Conversion and Management
Numerical / CFD
Solar chimney power plant
2013
Energy Conversion and Management
no
2013-10-26 12:00:00 00003356
computational studies on the effect of geometric parameters on the performance of a solar chimney power plant
2013
Energy Conversion and Management
Sandeep Kumar Singh Patel; Deepak Divashkar Prasad; Mohammed Rafiuddin Ahmed
10.1016/j.enconman.2013.09.056
Summary
ANSYS-CFX simulations of a small solar chimney power plant, 10 m tall with an 8 m collector, examine how collector inlet height, collector outlet size, chimney diameter and chimney divergence affect airflow and power. A slightly flared chimney (2°) combined with the narrowest collector opening performed best, as the smaller gap raises collector air temperature and thus mass flow and output.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source