Y. Quoc Nguyen; Viet T Nguyen · 10.1177/17442591221140465 https://doi.org/10.1177/17442591221140465 · 2022 · Building ventilation · Numerical / CFD
Journal of Building Physics
Building ventilation
Numerical / CFD
2022
Journal of Building Physics
journal
main
no
2022-12-17 12:00:00 00002275
characterizing the induced flow through the cavity of a wall solar chimney under the effects of the opening heights
2022
Journal of Building Physics
Y. Quoc Nguyen; Viet T Nguyen
10.1177/17442591221140465
Summary
CFD simulations of a wall-mounted solar chimney explore how inlet and outlet heights, with equal or unequal openings, shape the airflow in its cavity. Flow grows with opening height before levelling off; openings no taller than the air gap cut flow by about 27% when the left wall is heated and 85% when the right wall is, compared with the best layouts identified for each case.
Description written by Solar Tower. The original abstract is available from the publisher via the link below.
Open source