Dipak Kumar Mandal; Nirmalendu Biswas; Nirmal Kumar Manna; Dilip Kumar Gayen; Ali Cemal Beni̇m · 10.1038/s41598-023-46505-1 https://doi.org/10.1038/s41598-023-46505-1
Scientific Reports
An application of artificial neural network (ANN) for comparative performance assessment of solar chimney (SC) plant for green energy production Dipak Kumar Mandal; Nirmalendu Biswas; Nirmal Kumar Manna; Dilip Kumar Gayen; Ali Cemal Benim This study aims to optimize the power generation of a conventional Manzanares solar chimney (SC) plant through strategic modifications to the collector inlet height, chimney diameter, and chimney divergence. Employing a finite volume-based solver for numerical analysis, we systematically scrutinize influential geometric parameters, including collector height (hi = 1.85 to 0.1 m), chimney inlet diameter (dch = 10.16 to 55.88 m), and chimney outlet diameter (do = 10.16 to 30.48 m). Our findings demonstrate that reducing the collector inlet height consistently leads to increased power output. The optimal collector inlet height of hi = 0.2 m results in a significant power increase from 51 to 117.42 kW (~ 2.3 times) without additional installation costs, accompanied by an efficiency of 0.25%. Conversely, enlarging the chimney diameter decreases the chimney base velocity and suction pressure. However, as turbine-driven power generation rises, the flow becomes stagnant beyond a chimney diameter of 45.72 m. At this point, power generation reaches 209 kW, nearly four times greater than the Manzanares plant, with an efficiency of 0.44%. Nevertheless, the cost of expanding the chimney diameter is substantial. Furthermore, the impact of chimney divergence is evident, with power generation, collector efficiency, overall efficiency, and collector inlet velocity all peaking at an outer chimney diameter of 15.24 m (corresponding to an area ratio of 2.25). At this configuration, power generation increases to 75.91 kW, approximately 1.5 times more than the initial design. Remarkably, at a low collector inlet height of 0.2 m, combining it with a chimney diameter of 4.5 times the chimney inlet diameter (4.5dch) results in an impressive power output of 635.02 kW, signifying a substantial 12.45-fold increase. To model the performance under these diverse conditions, an artificial neural network (ANN) is effectively utilized.
Machine learning / AI
Numerical / CFD
Solar chimney power plant
2024
Scientific Reports
yes
2024-01-10 12:00:00 00001722
an application of artificial neural network (ann) for comparative performance assessment of solar chimney (sc) plant for green energy production
2024
Scientific Reports
Dipak Kumar Mandal; Nirmalendu Biswas; Nirmal Kumar Manna; Dilip Kumar Gayen; Ali Cemal Beni̇m
10.1038/s41598-023-46505-1
Abstract
This study aims to optimize the power generation of a conventional Manzanares solar chimney (SC) plant through strategic modifications to the collector inlet height, chimney diameter, and chimney divergence. Employing a finite volume-based solver for numerical analysis, we systematically scrutinize influential geometric parameters, including collector height (hi = 1.85 to 0.1 m), chimney inlet diameter (dch = 10.16 to 55.88 m), and chimney outlet diameter (do = 10.16 to 30.48 m). Our findings demonstrate that reducing the collector inlet height consistently leads to increased power output. The optimal collector inlet height of hi = 0.2 m results in a significant power increase from 51 to 117.42 kW (~ 2.3 times) without additional installation costs, accompanied by an efficiency of 0.25%. Conversely, enlarging the chimney diameter decreases the chimney base velocity and suction pressure. However, as turbine-driven power generation rises, the flow becomes stagnant beyond a chimney diameter of 45.72 m. At this point, power generation reaches 209 kW, nearly four times greater than the Manzanares plant, with an efficiency of 0.44%. Nevertheless, the cost of expanding the chimney diameter is substantial. Furthermore, the impact of chimney divergence is evident, with power generation, collector efficiency, overall efficiency, and collector inlet velocity all peaking at an outer chimney diameter of 15.24 m (corresponding to an area ratio of 2.25). At this configuration, power generation increases to 75.91 kW, approximately 1.5 times more than the initial design. Remarkably, at a low collector inlet height of 0.2 m, combining it with a chimney diameter of 4.5 times the chimney inlet diameter (4.5dch) results in an impressive power output of 635.02 kW, signifying a substantial 12.45-fold increase. To model the performance under these diverse conditions, an artificial neural network (ANN) is effectively utilized.
Abstract by the authors, reproduced under the CC BY 4.0 licence. Original publication via the link below.
Open source
PDF (open access)